Amlib
- Amlib known issues
-
There are no known issues at this time.
Connexion client
- Connexion client known issues
-
Find known issues for the Connexion client.
Connexion client 3.X known issues
Issue Details Macro slowness and freezing
Some users have reported issues when working with macros that use dialog screens that have caused macros to run slow or crash.
Workaround: Restarting Connexion client may help with macro slowness.
Affects: 2.63, 3.1
Running multiple Connexion windows at the same time
Due to the update to 64-bit, multiple instances of Connexion Client cannot run at the same time.
Workaround: Using the View > Pinned menu option within Connexion Client when looking at multiple records at a time or using a virtual machine to run multiple instances of Connexion Client at one time.
Affects: 3.1
Client 3.X is not compatible with unsupported versions of Microsoft Office
Connexion client 3.X is not compatible with versions of Microsoft Office that are no longer supported by Microsoft.
Workaround: If you are using an older, 32-bit version of Microsoft Office that is out of support, we suggest that you either upgrade your Microsoft Office to a newer, supported version; or, that you do not upgrade to Connexion client 3.X, but instead continue to use version 2.63.
Affects: 3.1
Help icon in the Connexion macro editor is no longer supported
In the Connexion macro editor and debugger, there is a question mark icon that would previously take users to macro-specific help. This icon utilized a feature that is no longer supported by Microsoft. Due to the nature of the language used to code the macro editor, we are unable to remove this icon from the user interface.
Workaround: There are two additional options for getting to the macro help:
-
Press the F1 key on your keyboard
-
Click on the Help menu above the toolbar, and then click Macro Help
Both options will take you to the OCLC Macro support site.
Affects: 3.1
Cannot maximize (re-display) Connexion client from a minimized position in the task bar
When you minimize the Connexion client, it becomes an icon in the task bar on your desktop, and you should be able to maximize/restore (redisplay) it by clicking the icon. If you are unable to maximize the client from the task bar icon, use one of the following workarounds.Workaround: Click the Connexion client icon in the task bar, and then press and hold the Windows key () on your keyboard while you click the <Up arrow> key or use Shift+Ctrl and right-click on the icon, then click Restore.
Affects: 2.63, 3.1
OCLC Gateway export destination no longer works after upgrading Connexion client
If you set up an OCLC Gateway export destination in a previous version of the client, export may not behave as expected after you upgrade to Client 3.X.Workaround: Check or reset options. - Navigate to Tools > Options > Export.
- From the Export tab, select OCLC Gateway export from the Destinations list and then click Edit.
- From the OCLC Gateway Export - Local System Settings window, check and correct settings if needed.
Affects: 3.1, 2.63
250 field in Constant Data overwrites existing 250 field when applied
The client does not recognize that the 250 field is repeatable. As a result, a 250 field in a constant data record will overwrite an existing 250 field when constant data is applied to a bibliographic record.Workaround: Enter the text you want to add to the 250 field in a tag that is not often used, and then change the tag number to 250 after you apply constant data.
Affects: 2.63, 3.1
MARCXML record export from online save file generates an error
If you are configured to export records in MARCXML, you will receive the following error message when attempting to export a single record from the online save file: Unable to cast object of type 'ConnexionUISchema.CDFRecType1' to type 'ConnexionUISchema.CDFRecType’Workaround: To avoid receiving an error message: - Use the local save file to export records
Or - Use batch export if exporting from the online save file
Affects: 2.63
Persian transliteration issues
The Persian transliterator:- Treats the romanized "th" as one character, Theh 062B. It should be treated as two characters, Teh 062A and Heh 0647.
- Does not transliterate characters following the romanized miagkii znak (prime mark) correctly.
Affects: 2.63, 3.1 Cannot access Connexion-client-specific macro commands from the OCLC Connexion Macro Editor and Debugger window
The Help button () in the OCLC Connexion Macro Editor and Debugger window does not work and cannot be fixed. See Use macros for help with macros.
Affects: 2.63, 3.1 Updating holdings on records imported into the client via Z39.50 (Tools menu) does not work
If you use Update Holdings to add a Z39.50-retrieved local system record to WorldCat (the client imports the record as a workform), you receive a message that field 001 is missing the OCLC number. As a workform, the record should not have an OCLC number in field 001. This is a system error.Workaround: Derive a new record from the Z39.50 imported record and then add to WorldCat using Update Holdings.
Affects: 2.63, 3.1
If you do not uninstall the client before upgrading, changing the "Install for everyone or just for you" setting during upgrade makes the client inoperable
Note: OCLC recommends uninstalling before you upgrade to prevent possible problems like this one.
When you upgrade the client without first uninstalling, in the window where you select an option to install for everyone who uses the workstation or just for you, you must select the same option you selected during your original installation. If you don't and the client becomes inoperable, you must uninstall and re-install the new version.
To determine which selection you made for the original client installation, check the location of the OCLC Connexion client desktop shortcut:- If you selected installation for you only, OCLC Connexion Client is listed in X:\Documents and Settings\[your username]\Desktop, where X = the letter of your hard drive.
- If you selected installation for everyone, OCLC Connexion Client is listed in X:\Documents and Settings\All Users\Desktop.
Affects: 2.63, 3.1 RDA Toolkit direct field link resolves to login screen
When the RDA Toolkit field help link is used within the bibliographic record editor, the link would resolve to the main RDA Toolkit login screen instead of directly to the specific field page.
Workaround: Login to the RDA Toolkit web page and navigate to the field page.
Affects: 2.63
The first time you display a WorldCat record using a new user profile, the record window is not maximized in the client window
The first WorldCat record displayed using a new user profile is a truncated view in the upper left part of the work area in the client window. To maximize the record window, use Window, Tile Vertically or Tile Horizontally.Affects: 2.63
For online constant data (CD) only, diacritics and special characters in CD name and CD My Status cause errors
Has been added as a Caution to client documentation and Help in the same topic specified in the known problem directly above. The cautionary note has a list of the characters that cause errors.Affects: 2.63, 3.1 MARC-8 Characters Verify no longer highlights non-MARC-8 characters
If you put characters that are outside of the MARC-8 character set into a record and perform the MARC-8 Characters Verify command, the change to accepting all Unicode characters prevents this function from isolating characters that are not part of the MARC-8 character set.Affects: 2.63, 3.1 Searches using characters above Unicode Plane Zero return incorrect results
Connexion client is currently unable to send the correct characters if characters entered are above the basic multilingual plane (BMP). The client handles Unicode characters in the BMP, which contains characters with a code point between U+0000 and U+FFFF. The BMP includes all the characters originally supported for cataloging in addition to many more. However, some language characters are found using supplementary planes and code points, such as CJK Unified Ideographs Extension B which has characters between U+20000 and U+2A6DF.Workaround: - In the client, change search argument to use only MARC-8 characters, could be switching to a name or subject that is all MARC-8 instead of what was originally entered.
Or - Use Record Manager.
Affects: 2.63, 3.1
CJK E-Dictionary search results are incomplete
When you use the E-Dictionary Search window (that is, click Tools > CJK E-Dictionary, enter an input code or character in the search box, select an input method and a script, and click Find), the E-Dictionary Search Results window shows only the EACC data in the first column. The other columns are missing data.Workaround: In the E-Dictionary Search Results window, double-click the EACC entry. The E-Dictionary Entry window opens, showing all of the codes that are supposed to display in the search results.
Affects: 2.63, 3.1
Issues with controlling headings
See Control headings for known issues that impact controlling headings in Connexion client 2.63.Affects: 2.63, 3.1 Connexion client 2.63 known issues
Note: Known issues are organized by type of functionality
Upgrade the client of your operating system
Issue Detail Notification you are not using the newest version of Connexion client
Some users are reporting after a Windows security feature update, they are seeing a pop up notification that says, "A new version of the Connexion client is available. You must upgrade to the new version before the announced cutoff date to continue using the client."
2.63 version will continue to be supported.
Workaround: Close the pop up notification.
2.63 version will continue to be supported.
Affects: 2.63
Macro slowness and freezing
Some users have reported issues when working with macros that use dialog screens that have caused macros to run slow or crash.
Workaround: Restarting Connexion client may help with macro slowness.
Affects: 2.63, 3.1
RDA Toolkit direct field link resolves to login screen
When the RDA Toolkit field help link is used within the bibliographic record editor, the link would resolve to the main RDA Toolkit login screen instead of directly to the specific field page.
Workaround: Login to the RDA Toolkit web page and navigate to the field page.
Affects: 2.63
False "Unidentified publisher" system warning in Windows 7, 8/8.1, and Windows 10 upon startup of client 2.63
If you use version 2.63 of the Connexion client in Windows 7, 8/8.1, or Windows 10, you receive the following Windows User Account Control (UAC) system warning each time you start the client:
An unidentified program wants access to your computer.
connex.exe
Unidentified publisher
"C:\Program Files (x86)\OCLC\Connexion\Program\Connex.exe"
The enhanced security in modern versions of Windows triggers UAC when the client is started. Click Yes to grant permission. The client will open and run as expected.
Downloading and installing the client Auto-fix will suppress UAC prompts when opening the client.Affects: 2.63 During upgrade, installation fails; you are asked for Connexion.msi path
In some cases, the upgrade installation may fail with a message asking the path to your Connexion.msi file. Please contact OCLC Support for help in resolving this problem.Affects: 2.63 The installation program may re-run the first time you open the client after installing the client-only software
If this problem occurs, it happens only the first time you run the new version. The problem does not affect the client's performance.Affects: 2.63 An OCLC Gateway export destination you set up before upgrading may not work after upgrading if you did not uninstall the previous client version
If you set up an OCLC Gateway export destination in a previous version of the client, export may not behave as expected after you upgrade to Client 2.63.Workaround: Check or reset options. - Navigate to Tools > Options > Export.
- From the Export tab, select OCLC Gateway export from the Destinations list and then click Edit.
- From the OCLC Gateway Export - Local System Settings window, check and correct settings if needed.
Affects: 3.1, 2.63
The first time you use the client shortcut icon () on the desktop to open the client after upgrading, you may get an error that prevents the shortcut from working
This problem may occur only for those who use Windows XP or Vista and run the client under a User security level. If this happens, create a new shortcut and delete the non-functional one:- Navigate to the Connex.exe file in X:\Program Files\OCLC\Connexion\Program\ (X = the letter of your hard drive).
- Right-click the Connex.exe file, and then click Create Shortcut.
- Drag the shortcut to the desktop. It becomes an icon.
- Right-click the original shortcut icon that did not work and click Delete to remove it from the desktop.
Tip: To shorten or change the name of the icon you created, single-click the text attached to the icon, and then single-click again to select and edit the text.Affects: 2.63 The client may be missing the graphical diacritics and special characters selection box after you upgrade if you did not uninstall the previous client version
The Enter Diacritics and Special Characters window ( Edit > Enter Diacritics) has both pictures of diacritics and characters and a drop-down list of their names, from either of which you can choose a character to enter in a record or a search. If you are missing the graphics in this window, close the client and all open programs, and then close down and restart your workstation.
Note: Even when the graphics are missing, you can still select a character from the list.
Affects: 2.63 If you do not uninstall the client before upgrading, changing the "Install for everyone or just for you" setting during the upgrade makes the client inoperable
Note: OCLC recommends uninstalling before you upgrade to prevent possible problems like this one.
When you upgrade the client without first uninstalling, in the window where you select an option to install for everyone who uses the workstation or just for you, you must select the same option you selected during your original installation. If you don't and the client becomes inoperable, you must uninstall and re-install the new version.To determine which selection you made for the original client installation, check the location of the OCLC Connexion client desktop shortcut:
- If you selected installation for you only, OCLC Connexion Client is listed in X:\Documents and Settings\[your username] \Desktop, where X = the letter of your hard drive.
- If you selected installation for everyone, OCLC Connexion Client is listed in X:\Documents and Settings\All Users\Desktop.
Affects: 2.63
You may be denied access to OCLC files after you upgrade, preventing you from running the client
You may receive an "Access denied" error the first time you run the client after installing. The error message lists a file starting in the X:\Program Files\OCLC\Connexion\Program folder and may list others. Access may be denied to the following files, among others:- UpdateVersion.xml
- InstallCustomAction.InstallState
- AppUpdate.log
To run the client in the users group, follow this one-time procedure:
- Log on to your workstation as Administrator.
- Add the User to the Administrators group.
- Log on as the User.
- Start the client. A series of progress bars will appear. When the progress bars finish processing, the client will open.
- Remove the User from the Administrators group.
- Log on as the User. Restart the client. You do not have to repeat this procedure.
Affects: 2.63
Zoeken
Issue Detail Change to heading appearance of headings in a browse list when the ending punctuation of the heading is different
As part of the Connexion install, changes have been made to authorities indexing. These include the resolution of the longstanding problem that resulted in misleading subfield codes:
Occasionally, a heading appears in browse results with a subfield code that is misleading. However, when you view the record, the subfield code that appears in the results list is not present in the record.
An example of this is browsing the LCSH index for the heading Noah's Ark. In the root index, the heading is presented as $t Noah's Ark; however, when you view the record, the heading Noah's Ark appears in $a, not $t. There is only a single subject authority record for Noah's ark, in which the heading appears only in $a (LCCN sh 85092133). But the text Noah's ark appears in $t in 9 other authority records.
As part of the new indexing, users will find a change in the appearance of headings in a browse list when the ending punctuation of the heading is different. This change to indexing results in multiple listings:
ROOT:
Poe, Edgar Allan, $d 1809-1849 1 record Poe, Edgar Allan, $d 1809-1849. 2 records Poe, Edgar Allan, $d 1809-1849 $c (Spirit) 1 record
EXPANDED:
Poe, Edgar Allan, $d 1809-1849 1 record E1.[100] 1 record E2.[700] 1 record E3.$t Fall of the house of Usher [500] 1 record E4.$ Gold bug [100] 1 record
In the Expanded list, both the [100] and [700] relate to the first record in the Root list, and E3 and E4, that have a period prior to the $t are represented in the second entry in the root list that contains a period at the end of the $a.Affects: 2.63
Internet Resources appear under Books in the group list, but actually are correctly retrieved by your search
Currently, records that meet specific requirements (presence of 856 with appropriate indicators) are given the primary document type of Internet Resources, but Connexion group lists do not yet include Internet Resources as a separate group heading. Instead, Internet resource records are included under Books in group lists, regardless of how the fixed field is coded. These groupings are for display purposes only, and reflect the actual format of the records, except for the inclusion of these Internet resources in any format.
For example, the search pb:naxos and hl:trios and mt:rec retrieves records for streaming video that are grouped under the Books format, even though the records are in the sound recordings format, with 006 fields for electronic resource/computer files, an 007 for sound recordings, and an 007 for the computer file.
You can limit a search to non-Internet items (not mt:url) to retrieve and display non-Internet items under the "correct" format heading in a group list. If you intend to retrieve both Internet and non-Internet items, be aware that any Internet resource records that match the search will be found under the Books format if you get a WorldCat group list.Affects: 2.63, 3.1 Searching authority records for headings that contain the percent (%) symbol
Do not use the % symbol when searching the authority file. In some cases, keyword searches that includes the percent (%) symbol may result in an error message.Affects: 2.63 Browsing authority records for personal names that have abbreviations followed by periods requires special treatment
Substitute a space for the period in a personal name that contains an abbreviation followed by a period.Example: Enter sca pn:L , Harry. Do not enter L., Harry or L, Harry.
Affects: 2.63
CJK script searches enclosed in double quotation marks are not working correctly
Enclosing a WorldCat search string in quotation marks ( "[search string"]) retrieves only records containing the exact search string matched character by character. Currently, however, if the search string is a CJK script string, the results include both records containing the exact string (correct) and records containing each character in the string (treated as a word) (incorrect).Affects: 2.63
The first time you display a WorldCat record using a new user profile, the record window is not maximized in the client window
The first WorldCat record displayed using a new user profile is a truncated view in the upper left part of the work area in the client window. To maximize the record window, use Window, Tile Vertically or Tile Horizontally.Affects: 2.63 Incorrect record counts in browse results for authority records
Browse results for authority records display headings and record counts from a list that the system does not update immediately when authority records are added or replaced. In the past, updates were immediate but caused an adverse effect on overall system response time. This was formerly a problem with WorldCat search results.Affects: 2.63 Connexion sorts words that include diacritics out of order in WorldCat derived and keyword search results
(Partly resolved with system changes November 2005 - resolved for derived search results only)
When WorldCat derived and keyword search results include words with diacritics, the records sort out of sequence with words that do not have diacritics.Examples: - A personal name derived search for lutz,m, results in the following order of records retrieved: Lutzki, Moses, Lutzky, M., Lutzky, Morton, Lütze, Max, Lützeler, Marga.
- A personal name keyword search for lutz, m* returns Lutz, Madeleine, Lütz, Manfred, and Lutz, Marcel, but Lütz, Manfred incorrectly appears first in the sequence.
Workarounds:- In the client only, you can click the column heading in the list to re-sort, although the re-sort is not always 100% correct.
Or - In the client, browse (scan an index) for the term instead–Connexion normalizes the headings by removing the diacritics, so the results display correctly.
Affects: 2.63
Caution: Whether to retain or omit a comma in a browse term for the LC names and subjects authority file depends on the index you browse
Retain a comma in a term you use to browse the LC authority file only when you browse the personal name index and the topical index. Exclude a comma from a term when you browse the LCSH index.Example: Browse for authors, english in the topicals index. Browse for authors english in the LCSH index.
Affects: 2.63
Caution: Copying and pasting browse terms that contain diacritics to browse the LC authority file may prevent Connexion from normalizing results correctly
If you paste terms that contain diacritics into the client from another program or file to browse the LC names and subjects authority file, Connexion may not be able to normalize the results correctly.Affects: 2.63 Edit
Issue Detail Highlight with the mouse from right to left to delete a field may shift data in next field
Has been added as a Caution to client documentation and Help.Affects: 2.63 Constant data
Issue Detail 250 field in Constant Data overwrites the existing 250 field when applied
The client does not recognize that the 250 field is repeatable. As a result, a 250 field in a constant data record will overwrite an existing 250 field when constant data is applied to a bibliographic record.Workaround: Enter the text you want to add to the 250 field in a tag that is not often used, and then change the tag number to 250 after you apply constant data.
Affects: 2.63, 3.1
For online constant data (CD) only, diacritics and special characters in CD name and CD My Status cause errors
Has been added as a Caution to client documentation and Help in the same topic specified in the known problem directly above. The cautionary note has a list of the characters that cause errors.Affects: 2.63, 3.1 Save constant data from the local save file to the online save file fails if online record already has a record with the same name
Has been added as a Caution to client documentation and Help in Cataloging/ Use Bibliographic Constant Data, Create, edit, or delete bibliographic constant data.Affects: 2.63, 3.1 Export
Issue Detail MARCXML record export from the online save file generates an error
If you are configured to export records in MARCXML, you will receive the following error message when attempting to export a single record from the online save file: Unable to cast object of type 'ConnexionUISchema.CDFRecType1' to type 'ConnexionUISchema.CDFRecType’Workaround: To avoid receiving an error message: - Use the local save file to export records
Or - Use batch export if exporting from the online save file
Affects: 2.63
Take actions
Issue Detail Incorrect record(s) deleted in online save file
The online save file screen does not automatically refresh after you delete initial records from the title list. The placement of the titles remains the same even though you have removed records from the list. As a result, it is possible to unintentionally delete records that you want to retain in subsequent deletions.Workaround: To avoid deleting incorrect records in subsequent deletions: - Open the record you want to remove and select Delete Record from the Action menu.
Or - Refresh the online save file screen each time you delete records from the title list.
Affects: 2.63
False error message may result from system duplicate detection when new authority records are added or master records are replaced
The system uses NACO Normalization rules to match the 1XX heading of any record you want to add or replace against the 1XX and 4XX name headings to detect duplicates. However, the system incorrectly ignores the first comma in subfield a, which results in an incorrect validation error message— This main entry exists in another authority record: LCCN=xx xxxxx ARN=ocaxxxxx. If you receive this message as a result of this problem, and the new/replace heading is not a duplicate, click OK to close the message, and simply re-issue the Add or Replace command to successfully add or replace the record.Affects: 2.63 An inappropriate message may appear when exporting authority records
On occasion, you may receive the following message when you export authority records: "This main entry exists in another authority record: LCCN=n ######## ARN=oca########." You receive the message as a result of a process that normalizes the main entry to help reduce duplicate records. Currently, tags are not considered in the normalization process.
The message occurs when you validate the record (Edit, Validate) before exporting or when you have the validation level set to "Full" in the Tools, Options, General tab (click Validation Level Options).If you used Edit, Validate, you can go ahead and export with no problem. If you have the validation level set to "Full," change it to "Basic" and then export the record.
Affects: 2.63
Control headings
Note: The following control headings known issues also impact Connexion client 3.X.
Issue Detail Cannot control compound headings
Compound headings containing ǂa[Geo] + ǂx History + ǂv Pictorial works or ǂv Sources cannot be controlled, even if they are valid. The suggested matches do not contain all of the subdivisions.
Example: 651 [blank] 0 Québec (Québec) ǂx History ǂv Pictorial works.
Example: 651 [blank] 0 Ohio ǂx History ǂv Sources.
Controlling headings that contain the subdivision Colonies causes the geographic subdivision to switch places with the topical subdivision
This combination of place with colonies is an issue within the heading control software for subjects. There is a portion of that process that looks at subdivisions and whether they can be geographically subdivided and then moves the geographic subdivision to that spot. In the case of these headings with colonies where you can further subdivide by a continent like Africa or Asia, we have two geographic subdivisions that are separated by a topical subdivision and the software doesn't get them into the correct order. We've known about this for a while and have a ticket in place with our developers to try and get that fixed, but that has not happened yet. So, once controlling is adjusted we'll be able to go back through and control them correctly. Otherwise, you ought to be able to add such a heading to a record, leave it uncontrolled, and make use of it that way.Example: - LCSH entered correctly: Indigenous peoples--France--Colonies
- Controlled LCSH: Indigenous peoples--Colonies--France
Punctuation: After controlling a heading, the punctuation in the controlled heading differs from the punctuation entered, and/or from the punctuation present in the authority record
When controlling headings, the system matches headings against the authority file. This matching process invokes a normalization process, which collapses all punctuation and spaces, removes subfield delimiters and codes, and is not case sensitive.Workaround: If punctuation is incorrectly altered when you control a heading, OCLC prefers that you leave the heading controlled and then report the heading to askqc@oclc.org.
A note about incorrect punctuation in the authority record:- If the authority record is not punctuated correctly, then the controlled heading in the bibliographic record will contain the same incorrect punctuation.
- If you are a NACO contributor and are authorized to correct the punctuation in the authority record, please do so.
- If you are not authorized to edit the authority record, please control the heading that contains the incorrect punctuation and then report the incorrectly punctuated authority record to authfile@oclc.org.
Bibliographic record contains "controlled" 6xx headings with second indicators other than 0
In some bibliographic records, headings tagged as 6xx with indicators other than 0 (zero) are incorrectly highlighted as controlled headings.Transliteration, diacritics, non-Latin scripts
Issue Detail Cursor does not always display at the end of the text when non-Latin script characters are pasted into a field
When non-Latin characters are pasted into a field, the cursor may display in the middle of the text instead of at the end.Affects: 2.63 Latin Letter Aveolar (U+01C2) and Khosian Languages
This character is also the subfield delimiter symbol in the client. The client interprets this character as a subfield delimiter and errors will occur if you attempt to use it in your bibliographic records for items in Khosian languages. Work in Record Manager if you need to use this character in your bibliographic records.Affects: 2.63, 3.1 MARC-8 Characters Verify no longer highlights non-MARC-8 characters
If you put characters that are outside of the MARC-8 character set into a record and perform the MARC-8 Characters Verify command, the change to accepting all Unicode characters prevents this function from isolating characters that are not part of the MARC-8 character set.Affects: 2.63, 3.1 Searches using characters above Unicode Plane Zero return incorrect results
Connexion client is currently unable to send the correct characters if characters entered are above the basic multilingual plane (BMP). The client handles Unicode characters in the BMP, which contains characters with a code point between U+0000 and U+FFFF. The BMP includes all the characters originally supported for cataloging in addition to many more. However, some language characters are found using supplementary planes and code points, such as CJK Unified Ideographs Extension B which has characters between U+20000 and U+2A6DF.Workaround: - In the client, change the search argument to use only MARC-8 characters, could be switching to a name or subject that is all MARC-8 instead of what was originally entered.
- Use Record Manager.
Affects: 2.63, 3.1
CJK E-Dictionary search results are incomplete
When you use the E-Dictionary Search window (that is, click Tools > CJK E-Dictionary, enter an input code or character in the search box, select an input method and a script, and click Find), the E-Dictionary Search Results window shows only the EACC data in the first column. The other columns are missing data.Workaround: In the E-Dictionary Search Results window, double-click the EACC entry. The E-Dictionary Entry window opens, showing all of the codes that are supposed to display in the search results.
Affects: 2.63, 3.1
Using the keystroke shortcut <Ctrl><D> to enter a subfield delimiter and code in non-Latin script data may not switch you back to the language/keyboard you were using, as it should, or may switch you to a different language
When you are entering non-Latin script data and use <Ctrl><D> to automatically switch to the English keyboard and back for entering a subfield delimiter and code, the client may not switch you back to the keyboard you were using after you enter the delimiter and code. You may remain in the English keyboard or you may be in a different keyboard.Workaround: To switch to the keyboard you need: - Click the language indicator in the Windows system tray (small blue box with two-letter codes), and then click the language/keyboard you need.
Or - Select by using the Windows default keystroke Left <Shift><Alt> to cycle through the language indicator list.
Affects: 2.63
In Connexion client version 2.00 and higher, the Microsoft Input Method Editor (MS IME) for Korean does not convert an existing Korean hangul character into a hancha or Chinese character
If you convert a hangul syllable into a hancha or Chinese character immediately after you enter it, the conversion works correctly. The conversion does not work if you highlight an existing hangul syllable and then try to convert. The IME does not allow you to choose a Chinese character. The problem occurs with hangul syllables in records; it does not occur when you convert a hangul syllable in the WorldCat quick search box on the toolbar (or in a text box in the Search WorldCat dialog).Workaround: Copy the hangul syllable you want to convert and paste into the WorldCat quick search text box, convert it to a Chinese character, and then and copy and paste back into the record.
Affects: 2.63
Other Persian transliteration problems
The Persian transliterator:- Treats the romanized "th" as one character, Theh 062B. It should be treated as two characters, Teh 062A and Heh 0647.
- Does not transliterate characters following the romanized miagkii znak (prime mark) correctly.
Affects: 2.63, 3.1 The Arabic transliteration tool handles some characters incorrectly
The list of incorrect characters has been added as a Caution in client documentation and Help in Cataloging/Use Non-Latin Scripts for Cataloging, Catalog using Arabic scripts.Affects: 2.63, 3.1 Macros
Issue Details Cannot access Connexion-client-specific macro commands from the Editor/Debugger Help window
The link in the Edit/Debugger Help window to open a list of Connexion-client-specific macro commands does not work and cannot be fixed. See Use macros for help with macros.Affects: 2.63, 3.1 Others
Issue Details Customized settings are lost
There are several possible causes for the corruption of files containing customized settings.
If you are having problems with losing your customized settings, please contact OCLC Support for help.- An application, process, or Windows itself shut down abnormally during a file write operation
This usually happens when something goes wrong while the file is being saved. The problem could be internet connectivity if the program is signed in to a service, or your computer suddenly loses power. Other problems include network issues, available computer resources, another running app or unstable process. If any of these things interrupt the process of writing to the file, the entire file may not be written or the hard drive “table of contents” does not get updated. - A physical hard drive is fragmented
This only applies to physical hard drives. Solid state drives are not affected. A fragmented hard drive creates more pieces in which the options.xml file will be stored. If the disk is defragmented, and the file can be stored in contiguous clusters, the write time to put the file back is reduced. - Antivirus software
Occasionally, antivirus software will register a false positive on the options.xml file, deleting it when the client closes and releases the file. - Windows folder redirection is storing all AppData settings on a shared network
Under certain circumstances, having the AppData settings on a shared network will cause an individual user’s options.xml file to be deleted each time they close and reopen the client.
Affects: 2.63
Thin blue line appears in the upper-left corner of Connexion client
When a record is collapsed, it may cause a thin blue line to display under the tool bar. This issue is typically caused by closing Connexion but leaving records open in Connexion.Workaround: Click the Windows menu, and then click either Tile Horizontally or Tile Vertically.
Affects: 2.63
Unable to open external links in Online Help
The online help system in Connexion client is having some compatibility issues with some of the external web pages to which it links.Workaround: If you are having difficulty opening an external web page, you can copy the web address from the Properties dialog, which is available on the right-click menu for the web link. To open the website, you can then copy this information and paste it directly into address field for your browser. You can also search for the content on the OCLC Support site or open the links from the documentation that is found on the Connexion Support Web site.
Affects: 2.63
Cannot maximize (re-display) Connexion client from a minimized position in the task bar
When you minimize the Connexion client, it becomes an icon in the task bar on your desktop, and you should be able to maximize (re-display) it by clicking the icon. If you are unable to maximize the client from the task bar icon, use the following workaround.Workaround: Click the Connexion client button in the task bar, and then press and hold the Windows key () on your keyboard while you click the <Up arrow> key.
Affects: 2.63, 3.1
Updating holdings on records imported into the client via Z39.50 (Tools menu) does not work
If you use Update Holdings to add a Z39.50-retrieved local system record to WorldCat (the client imports the record as a workform), you receive a message that field 001 is missing the OCLC number. As a workform, the record should not have an OCLC number in field 001. This is a system error.Workaround: Derive a new record from the Z39.50 imported record and then add to WorldCat using Update Holdings.
Affects: 2.63, 3.1
-
CONTENTdm
- CONTENTdm known issues
-
Issue Details Project Client 7.0.73.0 (December Release); 7.0.75.0 (February Release)
When OCR is being run on images, the progress message box shows inaccurate page counts.
Identified: December 2021
Workaround: Use the page counter shown in: Project Settings Manager > OCR > Page Limit. It should show you “#### of 10000 pages remaining this month”.
Project Client 7.0.73.0 (December Release); 7.0.75.0 (February Release)
We've deprecated the "Fast Mode" in OCR, but it is still showing in the settings interface. If you check this option, OCR is still processed with the same Best Quality setting.
Identified: December 2021
Workaround: Ignore the “Fast Mode” setting.
Project Client 7.0.32.0 (June Release); 7.0.73.0 (December Release); 7.0.75.0 (February Release)
Under certain situations, when editing metadata in spreadsheet view in Project Client, it flashes as it refreshes the screen.
Identified: December 2021
Workaround (Temporary): Switch to a different view or go to a different screen in Project Client. Then come back to the spreadsheet view
Project Client 7.0.32.0 (June Release); 7.0.73.0 (December Release)
Finding Aid (EAD) ingest does not work. You always receive an error message about the XML file being invalid.
Identified: January 2022
Fixed in version 7.0.75.0 (February 2022 release).
Cantaloupe has caused some issues with certain sites, such as PDF fonts display incorrectly in preview, some preview or expand view are missing for particular images or PDFs , or watermark doesn't work, etc. If you desire, we can roll your site back out of Cantaloupe.
There are 2 ways to rollback:
- Full rollback. The site will be completely off of Cantaloupe. Your images and PDFs will be processed by legacy image server. You'll lose PDF manifests, and the manifest generation will be back to the weekly update schedule. You won’t have access to IIIF Manifests for items with restrictions.
- Partial rollback. Only the display of image expand view and PDF preview will be rolled back to legacy. You’ll still enjoy the other benefits brought by Cantaloupe, such as have access to PDF manifests (but with fonts issue) and have dynamically generated manifests. But we did discover a bug with partial rollback where if you are: 1) on custom domain 2) have username restriction, then you will not be able to see image expand views.
So if you don’t have restriction, a partial rollback is ideal for you. If you do, you can consider a full rollback. Or wait till we fix the bug with partial rollback.
Workaround: Please contact Support to discuss possible rollback options.
FlexLoader Application fails to start - "Unable to start program because of the following error: The Web Services is unavailable. Please try again later. The underlying connection was closed. An Unexpect error o..
Identified: August 2022
No workaround available
"Full Size" image download option produces a "Proxy Error"
CONTENTdm end-user website "Full Size" image download link shows "Proxy Error" for very large/high-resolution image files
Identified: October 2018
Workaround: The file can be obtained for direct download using the GetFile API call. If a systemic issue with many files, please contact OCLC Support for guidance.
EZproxy
- EZproxy known issues
-
Installation & Configuration
Issue Details EZproxy on Windows unable to support LDAP over IPv6
Version Affected: V6.0 and later
EZproxy v6.0 added support for IPv6, but did not add this support to LDAP. EZproxy V6.1.6 made LDAP aware of IPv6 addresses, but the library support was not enabled correctly to support this, causing failures for sites that have both IPv4 and IPv6 addresses for their LDAP servers.
At this time LDAP support will be limited to IPv4 on Windows, but IPv6 will be supported on other platforms.
Security
Issue Details FREAK Vulnerability
EZproxy V5.7.44 and V6.0.7 are NOT vulnerable to the FREAK security issue IF you have the following settings in your config.txt:
Option DisableSSL40bit
Option DisableSSL56bit
Option DisableSSLv2Add the following directives to your config.txt to protect against the FREAK vulnerability:
Option DisableSSL40bit
Option DisableSSL56bit
Option DisableSSLv2Build issues
Issue Details Support for IPv6 Addresses via the EZproxy Location directive
Version affected: V6.0
EZproxy 6.0 does not support use of the Location directive to look up IPv6 addresses. We have not yet extended our support to the MaxMind V6 GeoLite database (GeoLiteCityv6).
Fix Date: TBD
A future version of EZproxy will incorporate new compatibility with IPv6 address lookup.
Using IPv4 addresses in IPv6 notation
Version affected: V6.0
Do not use IPv4 addresses in IPv6 notation format to determine whether or not to make IPv6 network calls. For example, the IPv4 address 127.0.0.1 will not be treated equivalently to the IPv6 0:0:0:0:0:ffff:7f00:1 address.
This is the designed behavior, and no remediation is planned
Dual Stack (IPv6/IPv4) cannot run when EZproxy is set to ProxyByPort
Version affected: V6.0
In order to provide support for IPv6 ProxyByPort, you must duplicate the database stanzas using IPv6 syntax.
This is the desired behavior, and no remediation is planned
The way we build EZproxy with OpenSSL
Version affected: V6.0 and earlier
Today we statically link OpenSSL’s binary library with EZproxy. We do this because this build method makes installation of EZproxy much easier for our EZproxy institutions--the institution doesn’t have to track and manage the OpenSSL version on their system.
We will further evaluate whether or not we should build EZproxy by dynamically linking OpenSSL, but we have no current plans to build EZproxy that way.
A 64 bit build of EZproxy
Version affected: V6.0 and earlier
Newer Windows and Linux systems are 64 bit-based operating systems, which provide a much larger address space for programs like EZproxy. Very few EZproxy institutions are seeing this memory limit, however a few are starting to bump up against it.
In some cases, a 64 bit version of the same program (such as the 64 bit Chrome browser) will run slightly faster than the 32 bit equivalent. Both Linux and Windows have very good facilities for running 32 bit applications on 64 bit operating systems. However the more significant issue for EZproxy is the memory limit.
Fix Date: TBD
Because of the potential memory limit issues (and it’s still pretty rare), we are planning to provide 64 bit builds of EZproxy V6.x in the future.
My Account
- My Account known issues
-
Issue Details The date format does not reflect my browser preference. To correct this issue, please ensure that your preferred language is correct in your browser and refresh your browser. In Chrome, your preferred language will need to be at the top of your list. If you have changed your language and if your currently set language on top of your language list is not reflecting the date formats, then try clearing browser history/cache and restarting your browser.
Please contact OCLC Support if you continue to have this issue.
See all fixed My Account known issues.
OCLC Usage Statistics
- OCLC Usage Statistics known issues
-
Issue Details
Relais D2D
- Relais 2D2 known issues
-
There are no known issues at this time.
Relais ILL
- Relais ILL known issues
-
There are no known issues at this time.
Tipasa
- Tipasa known issues
-
Issue Details Lending copy requests for Ebooks are not being deflected as expected based on the lender's eLicense deflection policy and ILL license terms = No. A fix is planned for this in January of 2025. Lending copy requests for parts of ebooks held in the WorldCat knowledge base sometimes display links that do not resolve to content, instead go to a URL ending with "null." A fix is planned for this in January of 2025. Duplicate knowledge base links appear in the Library's Holdings Information section of lending requests. We are currently investigating this issue and working toward a fix. When attempting to Print All Update in WorldShare ILL, the following error message displays:
"No patch list found in request body (required for REVIEWING actions)."
We are currently investigating this issue and working toward a fix. When a request is submitted with the patron request form, the issue/publication date is sometimes not retained in the request in the staff interface. In these cases, staff members need to manually look up the information or clarify which item the patron is requesting. Then, the request can be manually sent again through automation.
When you select "Clear with fee payment required (CCG)" while processing requests, a message that states "No best match found in the CCC results".
This message usually appears when more than one CCC match is found; however, it is errantly displaying when exactly one match is found.
In these cases, edit the ISSN field to include only one ISSN.
Please note that this message is a display issue and does not impact Copyright Clearance or CCC functionality.
Batch responding Yes as a lender results in an error message if Constant Data is applied during the batch process. Apply constant data using lending automation, or process requests individually. On resubmitted requests, the asterisk may not be displayed on the correct occurrence of the symbol in the lender string when the lender appears more than once. It will be displayed on the first occurrence in the string, even if the request has actually moved to the later occurrence.
This is purely cosmetic and does not affect functionality. Patron’s "Preferred Edition" is replaced with "Any Edition" in new borrowing requests that do not match an automation. New borrowing requests that match an automation display the patron’s Preferred Edition correctly. However, new requests that do not match an automation will display Any Edition, regardless of the value selected on the patron request form.
Borrowing staff can select a different value (“Most recent edition” or “This edition”) and lenders will see the correct value.
See all fixed Tipasa known issues.
WorldCat Discovery
- WorldCat Discovery known issues
-
Issue Details Report a Broken Link - We have updated reply emails for the "Report a Broken Link" form with the following changes:
- Email messages generated by the form now come from do-not-reply@e.worldcat.org instead of no-reply@e.worldcat.org.
- The header of email messages generated by the form no longer includes patron contact information. [NOTE: The "Send me the correct link" checkbox determines whether patron contact information displays in the body of emails.]
- In some cases the description field will display a "null" value when a message is entered in the form
- In some cases the Report a Broken Link email does not include the ISSN of the shared record in the body of the email, when the email is sent from the A-Z list page
- In some cases the link contained in the Report a Broken Link email does not direct email recipient back to the resource. Instead the link directs to a page with the message "We were unable to find direct full text links for this item is displayed"
Include sender's information in the body of the email Resolved: February 2024 Enable ability to 'reply-to' the user's email address Targeted Resolution: TBA Description field will include the sender's message instead of a "null" value Resolved: April 2024 Display ISSN in the body of the email Resolved: July 2024 Link directs to resource Resolved: July 2024 Share Record - We have updated reply emails for the "Share" form with the following changes:
- The header of email messages generated by the form no longer includes patron contact information.
Include sender's information in the body of the email Resolved: April 2024 Enable ability to 'reply-to' the user's email address Targeted Resolution: TBA Collection names on A-Z list: In some cases, the collection name as displayed in WorldShare Collection Manager and the collection name as displayed in WorldCat Discovery or the A-Z list do not match. Targeted Resolution: TBA Date format: Some locales are incorrectly displaying US Date format. Targeted Resolution: TBA Searches using wildcards: Wildcard and truncated searches are returning inconsistent results. Targeted Resolution: TBA Date (Newest First) sort: For some search results, some older materials are sorted first, above those published more recently. Targeted Resolution: TBA Incorrect holdings: For some articles the Access Options panel is blank
Targeted Resolution: TBA